Appendix B: Sensor Tables Intel
®
Server Board S5000PAL / S5000XAL TPS
Revision 1.7
Intel order number: D31979-010
90
Sensor
Name
Sensor
Number
System
Applica-
bility
Sensor Type Event /
Reading
Type
Event Offset
Triggers
Criticality Assert /
De-assert
Readable
Value /
Offsets
Event Data Rearm Standby
Fan 2
Present
61h Chassis-
specific
Fan
04h
Generic
08h
Device present OK As and De T A
Fan 3
Present
62h Chassis-
specific
Fan
04h
Generic
08h
Device present OK As and De T A
Fan 4
Present
63h Chassis-
specific
Fan
04h
Generic
08h
Device present OK As and De T A
Fan 5
Present
64h Chassis-
specific
Fan
04h
Generic
08h
Device present OK As and De T A
Fan 6
Present
65h Chassis-
specific
Fan
04h
Generic
08h
Device present OK As and De T A
Fan 7
Present
66h Chassis-
specific
Fan
04h
Generic
08h
Device present OK As and De T A
Fan 8
Present
67h Chassis-
specific
Fan
04h
Generic
08h
Device present OK As and De T A
Fan 9
Present
68h Chassis-
specific
Fan
04h
Generic
08h
Device present OK As and De T A
Fan 10
Present
69h Chassis-
specific
Fan
04h
Generic
08h
Device present OK As and De T A
Redundancy
regained
OK
Redundancy
lost
Redundancy
degraded
Degraded
Non-red: suff
res from redund
Non-red: suff
from insuff
OK
Fan
Redun-
dancy
6Fh Chassis-
specific
Fan
04h
Generic
0Bh
Non-red:
insufficient
Critical
As – Trig Offset A X
Vedere la pagina 88